Business and Trade Marketplace

Business and Trade Marketplace Blogs

What are the components of concrete pump truck

What are the components of concrete pump truck
henan haomei    machinery manufacturing co., LTD. Is a collection of concrete pump research and development, manufacturing, sales, leasing and maintenance in a body, a one-stop service of professional enterprise.Concrete pump truck, they are widely used in industrial and chemical fields .    we  introduce the composition of concrete pump truck parts  as follows : 1. The pump body and chassis hopper car. 2. Transport of cement elbow type folding line, is determined by the conveyance height of the folding. 3. The power part of the pump truck, the power part and two branches.Part one is to provide concrete pump works, if use the motor, is about 40 to 60 mw or higher.Second is the need to shore up the fold line part of the hydraulic system energy consumption is small. 4. The operation of the pump truck system and auxiliary small equipment. The above is composed of concrete pump truck parts.
  725 Hits
725 Hits

Concrete pump which improper use may cause damage

Concrete pump which improper use may cause damage
hengzhou haomei  machinery is a trustworthy company. Concrete pump in the process of use, must be in strict accordance with the instructions to use, if use undeserved, may cause the following 11 damage: 1, concrete, hydraulic oil splash, cement or other chemicals that cause formulated; 2, due to the hydraulic system maintenance without unloading hydraulic line cause damage; 3, the conveying pipe pressure caused by the open line damage; 4, pumps due to improper lifting or support capsized and cause damage; 5, transfer line, unsecured line sliding or loss and damage or pipe joints, pipe burst damage; 6, pump body parts into the hopper while working or damage caused by sports organizations; 7, high pressure hose burst damage; 8, when slide valve cylinder work, to repair the damage caused by grease system; 9, when the piston movement, the damage caused by hand into the washing room; 10, prevent blender or other rotating parts movement caused by the damage; 11, inside and outside the protection of cables damaged;Electrical component failure and damage caused by pump charged, caused by electric shock damage. Above is the concrete pump improper use may cause damage, hope to be of help. http://concrete-pump-cn.com
  666 Hits
666 Hits

Concrete pump tube four considerations

Concrete pump tube four considerations
H aomei   remind you when the concrete pump tube shall be carried out according to its technical parameters and specific situation, here we introduce for everybody four precautions: concrete pump tube A, vertical tube 1. The vertical tube, to reduce concrete pump outlet pressure, appropriate ground horizontal tube length is not less than a quarter of the vertical tube length, usually should not be less than 15 meters.Such as constraints can increase the bend or circular tube meet the demand. 2. When the vertical conveying distance, should be in a concrete pump machine Y tube discharging mouth 3-5 metres of conveying pipe root set pin valve to prevent concrete mixture reflux. Second, the down side tube 1. The down side cloth tube, when the elevation difference is greater than 20 meters, should be in the lower inclined tube set 5 times the length of the elevation difference of horizontal tube;Such as constraints, can increase the bend or annular pipe to meet the requirements of elevation difference length of 5 times. 2. When the slope is greater than 20 째, should first open the discharge valve, stay under the pipeline section concrete with a certain pressure, can close the discharge valve. Third, summer construction Hot season construction, should be cover with a damp cloth and straw bag to cover the conveying pipe, in order to avoid direct sunlight, tube concrete slump loss, transportation difficulties. Fourth, winter construction Cold season construction, appropriate USES heat preservation material in the conveying pipe, prevent concrete seas, and guarantee the concrete into the mold temperature. Above is the concrete pump tube four considerations.  
  587 Hits
587 Hits

 haomei concrete pump with low price high quality

 haomei concrete pump with low price high quality
USES the open hydraulic circuits, distributing valve, the constant power control, automatic compensation gap hydraulic automatic reversing and electric proportion control, the world's advanced technologies such as the concrete aspects of in-depth and meticulous research of the piston automatic lubrication test, won a number of patents, was developed on the basis of comprehensive domestic and foreign latest technology with international leading level of a new generation of products. haomei  mechanical drag pump is the domestic specifications of professional production base, can fully meet the different needs of various users.Drag pump completely using assembly line assembly, processing and assembly quality to strictly control each working procedure, each pulling the pump have been simulated condition overload experiment for final inspection, to ensure that the user first boot zero fault, on the basis of quality assurance, concrete pump prices are reasonable, and well received by consumers. http://concrete-pump-cn.com/product_category.php?id=4
  260 Hits
260 Hits

Harm about the phenomenon of concrete pump hydraulic system heat

Harm about the phenomenon of concrete pump hydraulic system heat
Concrete pump hydraulic system of fever, directly affects the normal work of the concrete pump, heating phenomenon caused harm, mainly include the following: (1) raise the temperature of working fluid, make work the viscosity of the liquid drops, the leakage of the pump increases, the actual flow of the pump have fallen; (2) hydraulic system and components of seal under the high temperature metamorphic, elastic degeneration ability lower, lower the sealing performance, even seal failure, leakage increase; (3) the work the viscosity of the liquid drop, lower the lubrication performance of the working fluid, the abrasion of hydraulic components, accelerated the wear failure of components, shorten the service life of the components; (4) when the valve core of hydraulic valve, the valve body material, thermal expansion coefficient at the same time, the different between valve core and valve body by thermal expansion valve core is jammed phenomenon, the concrete pump can work. In order to avoid the occurrence of the phenomenon, some concrete pump in use after a certain period of time, had to stop to make the system cooling, which reduces the concrete pump, is analyzed.the influence the construction progress.Fever, therefore, should be aimed at system reason, adopt corresponding measures to control the temperature of the hydraulic system, to ensure the normal use of concrete pump. H aomei  machinery company based on solid concrete pump design and manufacturing technology, carry out pump rental business. it  Has a strict training of concrete pump operating team and first-class maintenance technology service personnel team, existing HBT60 for leasing, more than 20 HBT80 type concrete pump units, and low taste high stock of spare parts warehouse, to ensure that meet all types of large and medium-sized industrial and public buildings, high-rise residential houses of concrete pumping construction requirements, concrete pump prices will make you more satisfied. http://concrete-pump-cn.com/product_category.php?id=5  
  405 Hits